0
No products in the cart.
Distribution Transformers Manufacturer | FIJ TECH
Factory:+86 17627795529
No products in the cart.
| Model Series | 35kV Power Transformer |
|---|---|
| Connection group grade | Yd11 or YNd11 |
| Rated capacity(KVA) | 30 ~ 3150 (KVA) |
| High voltage (kV) | 35 ~ 38.5 (kV) |
| Low voltage(kV) | 3.15/ 3.3/ 6.3/6.6/ 10.5/ 11(kV) |
| Short-circuit resistance(%) | 6.5 / 7.0/ 7.5 / 8.0 |
| Tapping range | +5% |
| Product Name | GCS Low-Voltage Drawout Switchgear |
|---|---|
| Model Code Meaning | G: Drawout type / C: Low-voltage / S: Switchgear |
| IP Rating | IP30 |
| Power users | three-phase AC frequency of 50Hz, a rated working voltage of 380V, and a rated working current of 4000A or less |
| Modular Dimension | 20mm (standard) |
| Cabinet Frame | Assembled with KS profiles (KB profiles optional) |
| Safety Design | Prevents contact with live parts; limits fault propagation |
| Product series | GGD Low-Voltage Distribution Cabinet |
|---|---|
| Power users | AC frequency 50Hz, rated voltage 380V |
| IP Protection Class | IP30 |
| Product dimensions | According to the user's drawings can be provided |
| Product Name | KYN28A-12 Indoor Metal-Clad Central Position Switchgear |
|---|---|
| Product Type | New-generation metal-clad switchgear with imported technology integration |
| Rated Voltage | 3.6kV / 7.2kV / 12kV |
| Rated Current | 630A ~ 4000A (630/1250/1600/2000/2500/3150/4000A) |
| Rated Frequency | 50Hz, Three-phase AC |
| "Five Prevention" Interlock Functions | ✅ Prevent operating circuit breaker under load |
| Protection Level | IP4X (enclosure), IP2X (when door opened) |
| Product Name | MNS Low-Voltage Drawout Switchgear |
|---|---|
| Model Code Meaning | M: Modular / N: Low-voltage / S: Switchgear |
| IP Rating | IP3X – IP4X |
| Power users | AC frequency of 50(60) Hz and a rated working voltage of 660V or less, |
| Cabinet Frame | C-profile modular structure; galvanized or aluminum-zinc coated plates |
| Expandability | Configurable doors, partitions, brackets, busbars per scheme requirements |
| Model Series | S13 Series Oil-Immersed Power Transformer |
|---|---|
| Connection group grade | Yyn0 or Dyn11 |
| Rated capacity(KVA) | 30 ~ 3150 (KVA) |
| High voltage (kV) | 10kV / 6.3kV / 6(kV) |
| Low voltage(kV) | 0.4(kV) |
| Short-circuit resistance(%) | 4.0 / 4.5 / According to customer needs |
| Tapping range | +5% |
| Model Series | S20 Energy Efficiency Stage 2 Oil-Immersed Transformer |
|---|---|
| Connection group grade | Yyn0 or Dyn11 |
| Rated capacity(KVA) | 30 ~ 2500 (KVA) |
| High voltage (kV) | 10kV / 6.3kV / 6(kV) |
| Low voltage(kV) | 0.4(kV) |
| Short-circuit resistance(%) | 4.0 / 4.5 / 5 / According to customer needs |
| Tapping range | +5% |
| Model Series | S22 Type Energy Efficiency Primary Oil Immersed Transformer |
|---|---|
| Connection group grade | Yyn0 or Dyn11 |
| Rated capacity(KVA) | 30 ~ 2500 (KVA) |
| High voltage (kV) | 10kV / 6.3kV / 6(kV) |
| Low voltage(kV) | 0.4(kV) |
| Short-circuit resistance(%) | 4.0 / 4.5 / 5 / According to customer needs |