Products

SC(B)H15 Amorphous Alloy Dry Type Power Transformer
Model Series

SC(B)H15 Amorphous Alloy Dry Type Power Transformer

Connection group grade

Dyn11

Rated capacity(KVA)

30 ~ 2500 (KVA)

High voltage (kV)

11 10 10.5 6.3 6 (kV)

Low voltage(kV)

0.4 (kV)

Short-circuit resistance(%)

4 / 6

Tapping range

±5% or ±2×2.5%

SCB14 Energy Efficiency Two-Stage Dry Type Transformer
Model Series

SCB14 Energy Efficiency Two-Stage Dry Type Transformer

Connection group grade

Yyn0 or Dyn11

Rated capacity(KVA)

30 ~ 2500 (KVA)

High voltage (kV)

10 6.3 6 (kV)

Low voltage(kV)

0.4 (kV)

Short-circuit resistance(%)

4 / 6 / 8

Tapping range

±5% ±2×2.5% ±3 or-1 x2.5%

SCB18 Energy Efficiency Level One Cast Resin Dry Transformer
Model Series

SCB18 Energy Efficiency Level One Dry-Type Transformer

Connection group grade

Yyn0 or Dyn11

Rated capacity(KVA)

30 ~ 2500 (KVA)

High voltage (kV)

10 6.3 6 (kV)

Low voltage(kV)

0.4 (kV)

Short-circuit resistance(%)

4 / 6 / 8

Tapping range

±5% ±2×2.5% ±3 or-1 x2.5%

SG(B)13 / SC(B)13 Dry-Type Transformer
Model Series

SG(B)13 / SC(B)13 Dry-Type Transformer

Connection group grade

Yyn0 or Dyn11

Rated capacity(KVA)

30 ~ 2500 (KVA)

High voltage (kV)

10 6.3 6 (kV)

Low voltage(kV)

0.4 (kV)

Short-circuit resistance(%)

4 / 6

Tapping range

+5%
+2×2.5%
or other

SH15 Amorphous Alloy Oil Immersed Power Transformer
Model Series

SH15 Amorphous Alloy Transformer

Connection group grade

Dyn11

Rated capacity(KVA)

30 ~ 2500 (KVA)

High voltage (kV)

11 10 10.5 6.3 6 (kV)

Low voltage(kV)

0.4 (kV)

Short-circuit resistance(%)

4 / 4.5 / 5

Tapping range

±5% or ±2×2.5%

XGN15-12 AC Metal-Enclosed Ring Network Switchgear
Product Series

XGN15-12 AC Metal-Enclosed Ring Network Switchgear

Application

special places that require automatic switching of dual power supplies, power distribution in urban residential areas, small secondary substations, switching stations, industrial and mining enterprises, shopping malls, airports, subways, wind power plants, hospitals, stadiums, railways, tunnels, etc.

IP rating

IP2X

YB Prefabricated Substation
Product series

YB Prefabricated Substation

Maximum ambient temperature

+40℃

Minimum ambient temperature

-25℃

Anti-rain level

Level 3

Contamination level

Level III

Power users

10kV, 50Hz, 30~1600kVA

Applicable

Public places, high-rise buildings, residential areas etc.

Installation location

Outdoor

ZGS Combined Substation
Product series

ZGS Combined Substation

IP Protection Class

IP33

Product dimensions

According to the user's drawings can be provided

Power users

AC 50Hz, 6~10kV, 30~2500kVA,

1 2